Felkoder

Nedan hittar du felkoderna för La Nordica Iside Idro 2.0.

AIR IN THE SYSTEM water
VARNING

Possible air in the system or lack of adequate circulation

Lösning

Vent the system, check circulation, ensure adequate safety zone

ALL CLEAN CHECK UP door
VARNING

Door not closed, ash drawer not closed, combustion chamber dirty, or flue exhaust pipe blocked

Lösning

Check hermetic door closure, check hermetic closure of ash drawer, check cleanliness of fumes pipe and combustion chamber

AUGER BLOCKED motor
KRITISK

Anomalous functioning of the motor

Lösning

Contact after-sales centre

AUGER CONTROL ALARM motor
VARNING

Anomalous pellet loading

Lösning

Contact after-sales centre

BOILER PROBE sensor
KRITISK

Boiler probe failure

Lösning

Contact after-sales centre

DAMAGE DEPR SENSOR sensor
KRITISK

Depression sensor defective, disconnected or faulty

Lösning

Contact after-sales centre

DEPRESSION ALARM sensor
VARNING

Door not closed, ash drawer not closed, combustion chamber dirty, flue exhaust pipe blocked, or flow sensor faulty

Lösning

Check hermetic closures, check cleanliness of fumes pipe and combustion chamber, contact after-sales centre if flow sensor faulty

EMPTY HOPPER other
VARNING

Pellet feed-box is empty or feed issues related to door, ash drawer, combustion chamber, or flue blockage

Lösning

Check pellet feed-box, check hermetic door and ash drawer closure, check cleanliness of fumes pipe and combustion chamber, contact after-sales centre

FUMES FAILURE motor
KRITISK

Fumes motor fault

Lösning

Contact after-sales centre

FUMES PROBE sensor
KRITISK

Fumes probe failure

Lösning

Contact after-sales centre

HOT EXHAUST temperature
VARNING

High flue gas temperature

Lösning

Check pellet feed adjustment. If problem persists, contact authorised technician

MAX H2O PRESSURE ALARM water
KRITISK

The pressure of the water has exceeded the max threshold

Lösning

Check that expansion vessels are not damaged or under-dimensioned, check that cold system is loaded at correct pressure, contact service centre if problem persists

MIN H2O PRESSURE ALARM water
KRITISK

System pressure is too low

Lösning

Check for air in system by venting, check for water leaks, check system components, contact service centre if problem persists

NO IGNITION power
KRITISK

Ignition failure or no current during ignition phase

Lösning

Check ignition procedures, check thermostat bulbs, set stove to OFF and repeat ignition procedure

NO PELLET other
VARNING

No pellet feed or pellet feed calibration inadequate

Lösning

Check pellet feed-box, adjust pellet flow, check motor reducer function

PRESSURE SENSOR DAMAGED sensor
KRITISK

Defective, disconnected or faulty differential pressure sensor

Lösning

Contact after-sales centre

PROBE H2O sensor
KRITISK

H2O probe failure

Lösning

Contact after-sales centre

PUFFER TANK PROBE sensor
KRITISK

Buffer tank probe failure

Lösning

Contact after-sales centre

TRAPDOOR BLOCKED other
VARNING

Automatic burn pot cleaning is blocked, burn pot dirty or clogged

Lösning

Check that burn pot is clear and clean, check door closure, contact service centre if problem persists

WATER OVERTEMP temperature
KRITISK

The water in the stove has exceeded 95°C

Lösning

Check system pressure, check circulator, contact authorised technician if problem persists

Felsökning

Praktiska tips för att lösa de vanligaste problemen med La Nordica Iside Idro 2.0.

Generator will not start power

Orsak: No power supply, damaged power cable, or ignition failure

Lösning

Check electrical connection, replace damaged power cable through authorised service, check ignition procedures and thermostat bulbs

Low heat output or poor combustion maintenance

Orsak: Dirty combustion chamber, clogged fumes pipe, inadequate pellet feed, or worn gaskets

Lösning

Follow monthly cleaning schedule, vacuum and clean flue pipe yearly, check and adjust pellet feed, inspect and replace worn gaskets

Pellets not feeding performance

Orsak: Empty hopper, motor reducer malfunction, or incorrect door/ash drawer closure

Lösning

Fill pellet tank, check motor reducer function, ensure door and ash drawer are properly closed

Water temperature too high temperature

Orsak: System pressure issues, air in system, or inadequate circulation

Lösning

Vent the system to remove air, check water pressure and circulation, verify expansion vessel condition, contact technician if persists

Water pressure too low water

Orsak: Air in system or water leaks in system components

Lösning

Vent the system, check for visible leaks in pipes and connections, verify system is filled to correct pressure

Automatic burn pot cleaning not working maintenance

Orsak: Burn pot clogged or blocked, or door not properly closed

Lösning

Clean and clear burn pot, ensure door is tightly closed, contact service centre if cleaning remains blocked

Generator stops unexpectedly power

Orsak: Power outage, thermostat set too low, or safety shutdown

Lösning

Wait for cooling to complete, check thermostat settings, contact after-sales centre if electrical issues suspected

Generator making unusual noise maintenance

Orsak: Dust or debris in fan or motor components

Lösning

Have authorised technician perform routine annual maintenance including fan disassembly and cleaning

Vanliga Frågor

De vanligaste frågorna om La Nordica Iside Idro 2.0.

Rutinunderhållet måste utföras minst en gång per år av en auktoriserad tekniker. Detta säkerställer korrekt funktion och upprätthåller garantivillkoren.

Vid slutet av säsongen rekommenderas att helt tömma pellettanken och använda en dammsugare för att rensa pelleter och damm från tanken. Stäng inte av apparaten från elförsörjningen för att låta pumpen utföra normala frysskyddscykler.

Röket bör vakuumeras och rengöras årligen eller när det är nödvändigt. Om det finns horisontella sektioner måste residuer avlägsnas innan de blockerar röret.

STAND-BY betyder att generatorn är avstängd och väntar på omtändning på grund av en extern termostat eller att alla begäranden har uppfyllts.

WATER OVERTEMP-larmet indikerar att vattnet i apparaten överskrider 95°C. Kontrollera systemtrycket, cirkulatorn och kontakta en auktoriserad tekniker om problemet kvarstår.

Extraame S.p.A. produkter är garanterade i 24 månader från köpdatum inom den europeiska gemenskapen. För kommersiella köp är garantin begränsad till 12 månader från köpdatum.

Om dörren eller askklotschen inte stängs ordentligt kan detta orsaka dålig täthetsförsegring och driftproblem. Kontrollera att båda är ordentligt stängda.Tetningarna måste inspekteras regelbundet och bytas om de är slitna eller skadade av en kvalificerad tekniker.

ANTIFREEZE-funktionen är aktiv när H2O-temperaturen understiger fabrikens inställda tröskel. Pumpen är aktiv tills vattnet når fördefinierad fabriksparameter +2°C.

Hjälp

Har du frågor om värmare Iside Idro 2.0 från La Nordica? Ställ dem direkt till vår expert! Du får information, praktiska tips och skräddarsydda lösningar på bara några sekunder.

Nedan hittar du bruksanvisningar för värmare som liknar Iside Idro 2.0. Prova även att se alla La Nordica värmare bruksanvisningar

Diskussion

Lämna en kommentar eller ställ en fråga

Delta i diskussionen

Ställ en fråga om bruksanvisningen eller lägg till ett användbart svar för andra användare.

Ange ditt meddelande här
Ange ditt namn
Ange din e-postadress